eXTReMe Tracker
 


Reference Project

 
Page :   <<Back  1 | 2 | 3   
 
 
Client : Idreco Asia Corporation
Location : Sripraya Plant, Bangkok
Type : Multi Stage
Year : 1993
Capacity : 25,000 CMH
Product : Odour Control System

Project Description ››
Multi stage scrubber is often used as air pollution control part of anaerobic wastewater treatment plant because of its low capital cost and easy to operate and maintenance. At Sipraya plant , total air capacity exhausted to the system is 15,000 CMH. In order to avoid discharge of drainage scrubbing liquid with too high or too low pH return to wastewater treatment plant , the system designed to utilize pH meter to adjust the pH.

The result from an independent laboratory shows that H2S emissions can be reduced by 95% using this technology.
 
Client : TCI Co.,Ltd.
Location : Samutsakorn
Type : Dust Collector
Year : 2001
Capacity : 30,600 CMH
Project Description ››
ACE supplied Dust Collector for serving ceramic process, which caused dust pollution by the spray dryer.
ACE's Dust Collector has the automatic overheat protection as well as the controlling system by Mini PLC.
 
 
Client : VON NORDENSKIOLD
Location : Samutprakarn wastewater Treatment
Product : GRP Pipes and Fittings
Type : DIN 16868 for Aeration System
Year : 2002
Quantity : 1,400 m.
Capacity : 30,600 CMH
Project Description ››
ACE Technologies supply GRP main pipe (dia. 400 mm.) for three basins included installation work. GRP pipes and fittings manufacturing comforms to GERMAN standard.
 

Client : Samsung Lotte (CEC Joint venture )
Location : Yannawa plant, Bangkok
Type : Multi Stages
Year : 1998
Product : Odour Control System
Project Description ››
The 22,000 m3/ h of malodorous air from domestic anaerobic waste water treatment plant ( YANNAWA) is exhausted into cross and parallel flow packed bed scrubber via polypropylene high static pressure fan (4000 Pa. ) The first chamber is acid to treat NH3 gas and the second is oxidizing chamber to oxidize mercaptan and H2S.
The semi - automatic system controlled by PLC was comprised with tools such as pH meter ,ORP meter, conductivity meter, level control switch,Ultrasonic level control, solenoid valve and drain valve. The effluent air samples were taken for analysis by an independent laboratory and showed qualities that exceeded BMA H2S consent requirement. (<0.01 ppm.)
[ Top ]
Page :   <<Back  1 | 2 | 3   

 
Member of Environmental Engineering Association of Thailand


76/5 Moo 3, Theparak Rd., K.M.10, Bangplee-Yai, Bangplee, Samutprakarn 10540. Thailand
Tel : +66 0-2759-7540 (20 lines) Fax : +66 0-2385-5211, 0-2759-7542
E-mail : info@aceco-th.com